If no or only historical values are displayed in the history graphs in the portal, your device does not transfer any data to the portal.

Approaches to solutions:

  • Make sure your device is equipped with the latest firmware.
    See "Software Version" info in the "Configuration -> System"menu. The version 2.16 or higher must be displayed there.
  • Check whether it is possible to access www.easycontrols.net from the network in which the device is installed.
  • If all these steps are unsuccessful, please call Customer Service at +49 (0)7720-606-742 or +44 (0)1206 228 500.

 

 

verlaufsgrafiken1

The use of the Helios Easycontrols portal with any number of devices is generally free of charge.

In the future, available premium features can be booked as soon as they are available.

Why is there a bypass flap in our KWL units? To direct the cooler and filtered fresh air past the cross-flow heat exchanger directly into your premises.
When is the bypass active? The bypass opens: If the user-defined period of time fits, the fresh air limitation has been exceeded, if the set room temperature is exceeded and if the drawn-in fresh air is cooler than the room temperature.
When does the bypass valve close again? The bypass is only closed when the outdoor air restriction or room set point temperature is not reached.
Why does the bypass not close even though the outdoor temperature is higher than your room temperature? Since your premises are colder than the fresh outside air drawn in, condensation increases. This is done on the wrong side of the device, so that water will escape from your KWL and damage and mould may occur.
When the bypass is activated, I get too warm? If the outside air temperatures are too warm, we recommend that the KWL unit adjusts the reduced range (fan stage 1). This means that they have filtered clean air and a controlled air exchange is guaranteed compared to an open window, for example.
How does passive fresh air cooling work? Some of our KWL (200,300,500) devices have this additional function. Although the room temperature is cooler than the outside temperature, the bypass damper will close despite increased condensation. However, they must also loosen a plug in the KWL unit to ensure that the condensate drains off.
What is the meaning of the "offset" supply air temperature? This function is active when the supplementary heating is switched on. The set "Offset" temperature is added to your room set point temperature, so that the bypass damper opens only after reaching the temperature sum. This avoids that the fresh air is heated unnecessarily.

 

 

User Rating: 3 / 5

Star ActiveStar ActiveStar ActiveStar InactiveStar Inactive

Sollte Sie kein Netzwerk-Kabel bis zum Aufstellungsort Ihres Easycontrols Geräts haben, so können Sie dieses auch über WLAN in ein bestehendes Funk-Netzwerk integrieren.Dazu verwenden Sie einfach einen beliebigen Access-Point welcher den Modus "Client" oder "Wireless Adapter" beherrscht.

No. Unfortunately, this is not possible.

The sensors and control units can be connected via RJ10 cable into commercial series. In the apparatus which depends on the last bus cable, the termination resistor must be connected.

The defective sensor no longer delivers measured values, whereby the control no longer considered this sensor.

All other sensors and controls run without restrictions.

Values of faulty sensors are no longer displayed in the web frontend.